Ruud PowerVent AP14236 Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Chauffe-eau et chaudières Ruud PowerVent AP14236. Ruud PowerVent AP14236 User's Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 36
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
VACATION
VERY
HOT
WARM
ABC
COOLER
HOTTER
VACATION
VERY
HOT
WARM
ABC
COOLER
HOTTER
AP14236 (05/07)
!
FOR YOUR SAFETY!
Do not store or use gasoline or other
flammable vapors or liquids or other
combustible materials in the vicinity of this or
any other appliance. To do so may result in an
explosion or fire.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not
use any phone in your building.
Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s
instructions.
If you cannot reach your gas supplier, call
the fire department.
Do not return to your home until authorized
by the gas supplier or fire department.
Improper installation, adjustment, alteration,
service or maintenance can cause property
damage, personal injury, or death. Refer to
this manual. Installation and service must be
performed by a qualified installer, service
agency or the gas supplier.
WARNING: If the information in these instructions is not followed exactly,
a fire or explosion may result causing property damage, personal injury or death.
!
The purpose of this manual is twofold: one, to provide the installer with the basic directions
and recommendations for the proper installation and adjustment of the water heater; and two,
for the owner–operator, to explain the features, operation, safety precautions, maintenance
and troubleshooting of the water heater. This manual also includes a parts list.
It is very important that all persons who are expected to install, operate or adjust this
water heater read the instructions carefully so they may understand how to perform
these operations. If you do not understand these instructions or any terms within it, seek
professional assistance.
Any questions regarding the operation, maintenance, service or warranty of this water heater
should be directed to the seller from whom it was purchased. If additional information is
required, refer to the section on “If you need service.”
Do not destroy this manual. Please read carefully and keep in a safe place for future
reference.
!
Recognize this symbol as an indication of Important Safety Information!
!
California Proposition 65 Warning: This product contains chemicals known to the
State of California to cause cancer, birth defects or other reproductive harm.
Residential 40, 50, 60 Gallon
Use & Care Manual
With Installation Instructions for the Installer
Printed in USA
Water Heaters
D
E
S
I
G
N
C
E
R
T
I
F
I
E
D
®
!
Warning: This water heater is not
suitable for use in manufactured (mobile) homes!
®
Residential Gas
Vue de la page 0
1 2 3 4 5 6 ... 35 36

Résumé du contenu

Page 1 - Water Heaters

VACATIONVERYHOTWARMABCCOOLERHOTTERVACATIONVERYHOTWARMABCCOOLERHOTTERAP14236 (05/07) ! FOR YOUR SAFETY!— Do not store or use gasoline or other f

Page 2 - READ THE SAFETY INFORMATION

10Installing the water heater.A new combination temperature and pressure relief valve, complying with the Standard for Relief Valves and Automatic Gas

Page 3 - WARNING!

WARNING: Do not attempt to convert this water heater for use with a different type of gas other than the type shown on the rating plate. Such conversi

Page 4 - IMPORTANT SAFETY INFORMATION

12Installing the water heater.The water heater must be installed with the factory supplied blower assembly in place.VentingThe water heater must be ve

Page 5 - AND NATURAL GAS MODELS

13Maximum and Minimum Vent Lengths for Residential 40 & 50 Gallon Power Vents ONLYNOTICE: The mixing of 2" and 3" vent pipe is not reco

Page 6 - SAVE THESE INSTRUCTIONS

14Installing the water heater.Number of 90° elbows with VentNumber of 45° ElbowsMaximum Vent Pipe Length in Feet (ft)0’ - 2,000’Maximum Vent Pipe Len

Page 7

15Additional Considerations Do Not install vent terminal under any patio or deck. To help prevent moisture from freezing on walls and under eaves,

Page 8

16NOTICE: All pipe, fittings, solvent cement, primers and procedures must conform to American National Standards Institute and American Society for Te

Page 9 - Water Supply Connections

17Installing the water heater.All joints in the vent piping must be properly sealed and the following materials are recommended:PVC materials should u

Page 10 - Installing the water heater

18WiringIf local codes permit, the water heater may be connected to electric service with the power cord provided (DO NOT use an extension cord). A gr

Page 11 - Gas Supply

For increased energy efficiency, some water heaters have been supplied with two 24” sections of pipe insulation. Please install the insulation, accord

Page 12

Care and CleaningDraining ... 27Maintenance ... 27Vent System Inspection ... 28Burner Inspection ... 28Extended Shut-Dow

Page 13

DO ❑ DO check inlet gas pressure to ensure that it is within the range specified on the rating plate. ❑ DO provide adequate air for c

Page 14

Installation ChecklistA. Water Heater LocationB. Water SupplyC. Gas SupplyD. Relief ValveE. Venting ❑ Close to area of vent. ❑ Indoors and protec

Page 15 - Additional Considerations

Tee fitting for vertical hot water supply lines.Hot water supply to houseFrom HOT outlet on water heaterHot water supply to heating unitSupplemen

Page 16 - Horizontal Vent Installation

Typical Piping Diagram for Combination Potable/Space Heating InstallationSpring loaded check valve in heating unit hot water supply line and cold wate

Page 17

Safety Precautions Do turn off manual gas shut-off valve if water heater has been subjected to over heating, fire, flood, physical damage or if the

Page 18 - SIZE: 6.5” X 5.5”

25Operating the water heater.Water Temperature Setting…Maximum water temperatures occur just after the burner has shut off. To determine the water tem

Page 19

26Sequence of Operation…During initial start-up or a call for heat, the control will verify the vacuum switch is open.Once the control verifies the bl

Page 20 - Heat Trap

27Care and cleaning of the water heater.Draining the Water Heater!CAUTION: Shut off gas to the water heater at the gas control (thermostat) gas cock o

Page 21 - Installation Checklist

28HousekeepingVisually inspect the hot surface ignitor.To ensure sufficient ventilation and combustion air supply, proper clearances must be maintaine

Page 22 -

29Vacation and Extended Shut-DownIf the water heater is to remain idle for an extended period of time, the power and water to the appliance should be

Page 23 - Lighting the water heater

Be sure to read and understand the entire Use and Care Manual before attempting to install or operate this water heater. It may save you time and mone

Page 24 - Operating the water heater

30Before You Call For Service…Troubleshooting TipsSave time and money! Review the charts on the following pages first and you may not need to call for

Page 25 - 2 seconds

31Problem Possible Causes What To DoRumbling noise Scale and sediment  Drain the water heater to remove scale and sediment from the tank.

Page 26 - Sequence of Operation…

Gas Valve LED Codes32CAUTION: Make certain power to water heater is “OFF” before removing protective cover FOR ANY REASON.CAUTION: Label all wires pri

Page 27 - Draining the Water Heater

33Replacement Parts.For 40 and 50 gallon models using natural or LP gas.Instructions For Placing a Parts OrderAll parts orders should include: The m

Page 30 - Before You Call For Service…

36IF YOU NEED SERVICE1. Should you have any questions about your new water heater, or if it requires adjustment, repair, or routine maintenance, it i

Page 31

Time/Temperature Relationship in Scalds Water Temperature Time To Produce a Serious Burn 120°F More than 5 minutes 125°F 11/2 to 2 minutes 130

Page 32 - LED Status Problem Solution

5LP and Natural gas have an odorant added to aid in detecting a gas leak. Some people may not physically be able to smell or recognize this odorant. I

Page 33 - Replacement Parts

6IMPORTANT SAFETY INFORMATION.READ ALL INSTRUCTIONS BEFORE USING.!WARNING!For your safety, the information in this manual must be followed to minimize

Page 34

Combustion Air Inlet OpeningsInstalling the water heater.This water heater must be installed in accordance with these instructions, local codes, utili

Page 35

8Installing the water heater.Combustion and Ventilation AirVentilation (ambient) air temperature must be 100°F or less. Proper operation of the water

Page 36 - IF YOU NEED SERVICE

9Thermal ExpansionDetermine if a check valve exists in the inlet water line. Check with your local water utility company. It may have been installed